Specification of

Arrester Dehnvap DVA CSP 60 E Is The Best Arrester  Because Of The Quality And High Performance To Protect Sensitive Component Of Electrical Panel System. Arrester Dehnvap DVA CSP 60 E Can Be Apply In Base Transceiver Station ( BTS ) Electric Panel And Rack System To Protect All Sensitive Component. Arrester Dehnvap DVA CSP 60 E Can Be Found In Our Company.

Dehnvap DVA CSP 60 E Main Technical Parameter Type 

Test Criteria Cellsite Surge Protector
Nominal Voltage    230V
Nominal Voltage ( Maximum Uc)    255V
Nominal The Discharge Current ' 8/20) 30 KA
Maximum Discharge Surge Current ' 8/80)  60 KA
Maximum Accepted Value Of The Follow-On Current    200A
Thunder And Lightning Impulse Current ( 10/350)    10KA
The Grade Of Voltage Protection Is In 5KA ' 8/20)    < 1KV
The Thunder And Lightning Pulse Assaults 1.2/50 Of Voltage    < 1.5KV
Response Time    < 25NS
Intensity Of Safety Fuse Of Maximum    125A Gl/GG
Current Strength Of The Short Circuit    50KA/50Hz
Operating Temperature    -400C ...+ 800C
Module Npe 
Nominal Voltage Uc    
255 V/50-60 Hz
Section Of Conductor    Minimum 10Mm2 Single Conductor, The Single Conductor Of Maximum 35Mm2 Many Strand Cables / 25Mm2
Mounting Frame    35Mm Guide Rail, According To EN 50 022
Outer Cover Material    Thermoplastic Glass Fibre Material Of White Ruggedization
Protect The Grade    General Type
Specification Size 4 Standard Module Din 43880S
Information Of Ordering Goods
Item Model    Description Of Products
Dehnvap DVA CSP 60 E The Three-Phase Four-Wire General Type Power Lightning Arrester Takes The Module Of Unexplosive
Dehnvap DVA CSP 60 E   General Type Power Lightning Arrester Of Three-Phase Four-Wire
Dehnvap DVA CSP 60 E Single-Phase Line Two General Type Power Lightning Arrester
Dehnvap DVA CSP 60 E The Three-Phase Four-Wire General Type Power Lightning Arrester Takes The Unexplosive Module Sound And Light Alarm
Dehnvap DVA CSP 60 E Single-Phase Line Two General Type Power Lightning Arrester Brought The Module Of Unexplosive

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot